Standards include: 1. Infrastructure standards; 2. Environmental standards; 3. Equipment standards; 4. Auxiliary area settings; 5. Lightning protection grounding system requirements; 6. Power environment monitoring system requirements; 7. Fire protection Alarm system requirements; 8. Anti-theft alarm system requirements; 9. Security system requirements; 10. Power supply and distribution system requirements, etc. Detailed introduction: 1. Infrastructure standards: including a series of elements such as computer room layout, strong electricity, weak electricity, power, air conditioning, fire protection, and safety. Strict safe, reliable, and efficient computer room construction standards need to be formulated to meet the high availability and maintainability of the data center.
The standards for data center IDC computer room construction mainly include the following aspects:
Infrastructure standards: including a series of elements such as computer room layout, strong electricity, weak electricity, power, air conditioning, fire protection, and safety. Strict safe, reliable, and efficient computer room construction standards need to be formulated to meet the high availability and maintainability requirements of the data center.
Environmental standards: The environment of the computer room needs to meet certain control requirements, including air, noise, temperature and humidity, etc. In particular, the temperature and humidity must be controlled within a certain range to ensure the normal operation of the equipment in the computer room.
Equipment standards: Various equipment in the computer room must comply with relevant national standards, including equipment frames, servers, switches, routers, cabinets, etc. These equipment also need to meet the requirements of high efficiency, low consumption, and high stability to improve the operation quality of the computer room.
Auxiliary area settings: The auxiliary area includes the customer reception area, customer operation area, monitoring room, key customer rest area, conference room, etc., which can be selectively set according to actual functional needs. Provide comprehensive customer service.
Lightning protection grounding system requirements: power supply lightning protection and surge protection, equipotential bonding, electrostatic discharge, grounding system, etc., to improve the stability and security of the data center.
Power environment monitoring system requirements: The computer room environment monitoring system can monitor the temperature and humidity, smoke detection, water leakage detection and other environmental parameters of the data center in real time to ensure that the operating environment of the data center is in good condition.
Fire alarm system requirements: The fire alarm system should have fire detection, alarm and fire extinguishing functions to ensure the fire safety of the data center.
Anti-theft alarm system requirements: Infrared alarm systems can monitor the intrusion of the data center in real time and ensure the security of the equipment and data in the data center.
Security system requirements: Access control, video surveillance, etc. can monitor the access and security status of the data center in real time to ensure the safe operation of the data center.
Power supply and distribution system requirements: The power supply system, power distribution system, lighting, emergency lighting, etc. should meet the operational needs of the data center, and equipment such as backup power supply and backup generator sets should be provided to Ensure the stable operation of the data center.
In general, the construction of data center IDC computer rooms needs to follow strict standards and specifications to ensure the stability and security of the data center. At the same time, factors such as energy conservation, environmental protection, and sustainable development also need to be considered to achieve sustainable development of the data center.
The above is the detailed content of What are the standards for the construction of data center IDC computer rooms?. For more information, please follow other related articles on the PHP Chinese website!