Home >Database >Mysql Tutorial >Linux 服务器自动关闭_MySQL

Linux 服务器自动关闭_MySQL

WBOY
WBOYOriginal
2016-05-31 08:46:141574browse

公司linux 服务器出现问题,mysql 服务器无故关闭,一直找不到原因。Version: '5.6.13-enterprise-commercial-advanced' socket: '/var/lib/mysql/mysql.sock' port: 3306 MySQL Enterprise Server - Advanced Edition (Commercial)2014-07-11 08:27:07 13597 [Warning] IP address '120.199.4.30' could not be resolved: Name or service not known2014-07-11 08:28:56 13597 [Warning] IP address '112.124.53.180' could not be resolved: Name or service not known140711 18:45:15 mysqld_safe Number of processes running now: 0140711 18:45:15 mysqld_safe mysqld restarted2014-07-11 18:45:17 1040 [Note] Plugin 'FEDERATED' is disabled.2014-07-11 18:45:17 1040 [Note] InnoDB: The InnoDB memory heap is disabled2014-07-11 18:45:17 1040 [Note] InnoDB: Mutexes and rw_locks use GCC atomic builtins2014-07-11 18:45:17 1040 [Note] InnoDB: Compressed tables use zlib 1.2.32014-07-11 18:45:17 1040 [Note] InnoDB: Using Linux native AIO2014-07-11 18:45:17 1040 [Note] InnoDB: Using CPU crc32 instructions2014-07-11 18:45:17 1040 [Note] InnoDB: Initializing buffer pool, size = 128.0MInnoDB: mmap(137363456 bytes) failed; errno 122014-07-11 18:45:17 1040 [ERROR] InnoDB: Cannot allocate memory for the buffer pool2014-07-11 18:45:17 1040 [ERROR] Plugin 'InnoDB' init function returned error.2014-07-11 18:45:17 1040 [ERROR] Plugin 'InnoDB' registration as a STORAGE ENGINE failed.2014-07-11 18:45:17 1040 [ERROR] Unknown/unsupported storage engine: InnoDB2014-07-11 18:45:17 1040 [ERROR] Aborting2014-07-11 18:45:17 1040 [Note] Binlog end2014-07-11 18:45:17 1040 [Note] Shutting down plugin 'partition'2014-07-11 18:45:17 1040 [Note] Shutting down plugin 'ARCHIVE'2014-07-11 18:45:17 1040 [Note] Shutting down plugin 'BLACKHOLE'2014-07-11 18:45:17 1040 [Note] Shutting down plugin 'PERFORMANCE_SCHEMA'2014-07-11 18:45:17 1040 [Note] Shutting down plugin 'INNODB_SYS_DATAFILES'2014-07-11 18:45:17 1040 [Note] Shutting down plugin 'INNODB_SYS_TABLESPACES'2014-07-11 18:45:17 1040 [Note] Shutting down plugin 'INNODB_SYS_FOREIGN_COLS'2014-07-11 18:45:17 1040 [Note] Shutting down plugin 'INNODB_SYS_FOREIGN'2014-07-11 18:45:17 1040 [Note] Shutting down plugin 'INNODB_SYS_FIELDS'2014-07-11 18:45:17 1040 [Note] Shutting down plugin 'INNODB_SYS_COLUMNS'2014-07-11 18:45:17 1040 [Note] Shutting down plugin 'INNODB_SYS_INDEXES'2014-07-11 18:45:17 1040 [Note] Shutting down plugin 'INNODB_SYS_TABLESTATS'2014-07-11 18:45:17 1040 [Note] Shutting down plugin 'INNODB_SYS_TABLES'2014-07-11 18:45:17 1040 [Note] Shutting down plugin 'INNODB_FT_INDEX_TABLE'2014-07-11 18:45:17 1040 [Note] Shutting down plugin 'INNODB_FT_INDEX_CACHE'2014-07-11 18:45:17 1040 [Note] Shutting down plugin 'INNODB_FT_CONFIG'2014-07-11 18:45:17 1040 [Note] Shutting down plugin 'INNODB_FT_BEING_DELETED'2014-07-11 18:45:17 1040 [Note] Shutting down plugin 'INNODB_FT_DELETED'2014-07-11 18:45:17 1040 [Note] Shutting down plugin 'INNODB_FT_DEFAULT_STOPWORD'2014-07-11 18:45:17 1040 [Note] Shutting down plugin 'INNODB_METRICS'2014-07-11 18:45:17 1040 [Note] Shutting down plugin 'INNODB_BUFFER_POOL_STATS'2014-07-11 18:45:17 1040 [Note] Shutting down plugin 'INNODB_BUFFER_PAGE_LRU'2014-07-11 18:45:17 1040 [Note] Shutting down plugin 'INNODB_BUFFER_PAGE'2014-07-11 18:45:17 1040 [Note] Shutting down plugin 'INNODB_CMP_PER_INDEX_RESET'2014-07-11 18:45:17 1040 [Note] Shutting down plugin 'INNODB_CMP_PER_INDEX'2014-07-11 18:45:17 1040 [Note] Shutting down plugin 'INNODB_CMPMEM_RESET'2014-07-11 18:45:17 1040 [Note] Shutting down plugin 'INNODB_CMPMEM'2014-07-11 18:45:17 1040 [Note] Shutting down plugin 'INNODB_CMP_RESET'2014-07-11 18:45:17 1040 [Note] Shutting down plugin 'INNODB_CMP'2014-07-11 18:45:17 1040 [Note] Shutting down plugin 'INNODB_LOCK_WAITS'2014-07-11 18:45:17 1040 [Note] Shutting down plugin 'INNODB_LOCKS'2014-07-11 18:45:17 1040 [Note] Shutting down plugin 'INNODB_TRX'2014-07-11 18:45:17 1040 [Note] Shutting down plugin 'CSV'2014-07-11 18:45:17 1040 [Note] Shutting down plugin 'MEMORY'2014-07-11 18:45:17 1040 [Note] Shutting down plugin 'MyISAM'2014-07-11 18:45:17 1040 [Note] Shutting down plugin 'MRG_MYISAM'2014-07-11 18:45:17 1040 [Note] Shutting down plugin 'sha256_password'2014-07-11 18:45:17 1040 [Note] Shutting down plugin 'mysql_old_password'2014-07-11 18:45:17 1040 [Note] Shutting down plugin 'mysql_native_password'2014-07-11 18:45:17 1040 [Note] Shutting down plugin 'binlog'2014-07-11 18:45:17 1040 [Note] /usr/sbin/mysqld: Shutdown complete140711 18:45:17 mysqld_safe mysqld from pid file /var/lib/mysql/AY130903103246702238Z.pid ended

更多

Statement:
The content of this article is voluntarily contributed by netizens, and the copyright belongs to the original author. This site does not assume corresponding legal responsibility. If you find any content suspected of plagiarism or infringement, please contact admin@php.cn